The Premaerix™ gas mixer is designed for precise control of gas concentrations across a wide range of flow conditions. Its integrated, low-noise system enables consistent delivery without the complexity of traditional gas mixing setups.
Overview
The Premaerix™ gas mixer is engineered to deliver precise, repeatable gas concentrations across the full operating range, including true zero flow. Built on patent-pending technology, the system addresses common limitations of traditional gas mixing setups, such as complexity, instability at low flow rates, and reliance on multiple external components. By integrating mixing, compression, and control into a single, compact platform, this system enables consistent performance for sensitive applications including cell culture, microfluidics, and organoid research.
The system is designed for dependable operation and seamless lab integration. A near-silent compressor, compact footprint, and enclosed architecture support use in space-constrained and noise-sensitive environments, while integrated filtration and condensate management enable continuous operation with minimal intervention. With flexible control options, including touchscreen interface and API-enabled connectivity, the Premaerix gas mixer provides a balance of precision, usability, and cost efficiency for modern life science workflows.
Precise
Deliver accurate gas concentrations across flow rates, including zero.
Quiet
Blend seamlessly into lab setups and work quietly with discreet mixing.
Reliable
Minimize reliance on premixed gas cylinders.
Safe
Work safely with a built-in 0.4-micron filter for IEC 61010-1 2017 compliance.
Compact
Save space in crowded labs and countertops.
Affordable
Expertly engineered to deliver maximum cost efficiency.
Specifications
Power
100 – 240 VAC, 50/60 Hz
CO2 pressure
(100%)
40 – 125 psig
Air alternative gas
(pre-mix)
40 – 45 psig
Communication protocol
CAN bus
1: Adjustable pressure/vacuum
-5 to 5 psig +/- 0.25% F.S.
2: Adjustable pressure/vacuum
-5 to 5 psig +/- 0.25% F.S.
3: Adjustable pressure
(pre-mix)
0 to 5 psig +/- 0.25% F.S.
4: Adjustable pressure
0 to 5 psig +/- 0.25% F.S.
5: Fixed 5 psig
5 psig +/- 0.1% psig
Output gas concentration
0 to 10% CO2 +/- 0.1%
Flow rate, maximum
300 SCCM
Flow rate, minimum
0 SCCM
Gas mixer size
10.3″ W x 10.3″ L x 5.9″ H
Gas mixer weight
20 lb
Gas mixer noise
(pre-mix)
< 45 dB
HMI screen
10.1”, IPS, 1280 x 800
HMI size
9.6″ W x 6.9″ L x 2.4″ H
HMI weight
2.2 lb
Specifications subject to change.